FR series


Test Items Test method Unit FR240 FR240-2 FR200GF FR243GF FR253-5
Density ASTM D792 g/cm3 1.33 1.33 1.42 1.61 1.29
Melt Flow Rate (230℃ 2.16kg) ASTM D1238 g/10min 4 7 3 5 5 *2
Tensile Properties Strength ASTM D638 MPa 32 31 35 47 10
Elongation at Break % 8 11 5 4 486
Flexural Properties Strength ASTM D790 MPa 50 51 55 67
Modulus MPa 4,000 4,010 4,560 6,200
Izod Impact Strength Notched ASTM D256 kJ/m2 3 3 5 28
Flammability
(Thickness of Test Piece)
UL94 V-0
(0.75mmt)
V-0
(0.75mmt)
V-0
(1.5mmt)
Our own method *1 V-0
(1.6mmt)
V-0
(1.6mmt)
Product Features Rigidity High Strength
High Rigidity
Semirigid

*1 Combustibility test Our own method: Test method equivalent to UL 94
*2 Melt flow rate measurement conditions: 190 ° C 2.16 kg

Caution
1. Data in this show sample figures measured under certain specific conditions.
2. Usage of products in this catalogue does not warrant a successful result of applications of the product for specific usage.
3. In case of product used for purpose and usage introduced in this catalogue, please pay attention to industrial property rights of third party which may relate to such use.
4. In case of product used for medical device, please consult with the manufacturer before such use.
5. Please notice that the content of this catalogue may be altered from time to time according to improvement of products without prior note.
Go to page top