special grade

Grade classification glass fiber content grade name Purpose
special grade
non-reinforced SP130 Automobiles, electronic parts
GF15% SP140
GF30% SP151
non-reinforced SW130 Drinking water, food (JPN)
  • The uses described in this document do not guarantee the results of applying this product to those uses.

  • When using the product for the purposes introduced in this document, please be careful about infringing on industrial property rights (patent rights, utility model rights, design rights, trademark rights). (Our company is not responsible for infringement of industrial property rights.)

  • It cannot be used for medical equipment or medical products.

  • If the product is to be used in food utensils or packaging, please have our sales representative thoroughly confirm the compatibility of the applicable grade with relevant laws and regulations (Food Sanitation Law, etc.) before signing the delivery specifications. I will do it.

  • It is the customer's responsibility to check the compliance of products processed by the customer with various laws and regulations using our products as raw materials.

  • Please note that the contents of this document are subject to change without notice due to improvements.

SP130, SP140, SP151

A grade for plating. Most grades of "ZALEC" can be electroless plated by selecting an appropriate process, but in particular when sufficient adhesion strength of the plating layer is required for thin-walled molded products, the plating-specific grade of this series is suitable. Suitable.

SP130 is unreinforced, SP140 is reinforced with 15% glass fiber, and SP151 is reinforced with 30% glass fiber, so you can use them depending on the required rigidity, dielectric constant, specific gravity, etc.

Suitable for precision plated electrical and electronic parts such as MIDs, shield cases, and antennas.

SW130

It is not reinforced and has a good appearance.
This grade has appropriate elastic modulus and heat resistance due to the addition of non-material filler, making it suitable for trays, etc.

Physical properties table

October 1, 2020

Test items Measurement method (Measurement condition) Unit SP130 SP140 SP151 SW130
ISO material display >PS-ST-MD25< >PS-ST-GF15< >PS-ST-GF30< >PS-ST-MD25<
NSF color
physical properties
density ISO 1183 g/cm3 1.18 1.31 1.41 1.21
glass fiber content wt% 15 30
Water absorption rate ISO 62 24h 50%RH 0.01 0.01 0.02 0.02
Mechanical properties
Tensile breaking strength ISO 527 MPa 35 75 100 Y38
tensile modulus MPa 3,200 6,500 11,000 3,800
Tensile elongation at break 3.4 2.5 2.1 3.3
bending strength ISO 178 MPa 65 120 165 72
bending modulus MPa 3,000 6,100 9,800 3,400
Izod impact strength ISO 180 With notch at 23℃ kJ/ m2 4 10 10 3
No notch at 23℃ 29 29 29 20
Charpy impact strength ISO 179 With notch at 23℃ kJ/ m2 4 10 9 3
No notch at 23℃ 41 33 32 30
thermal properties
Load deflection temperature ISO 75A 1.8MPa 100 175 230 98
ISO 75B 0.45MPa 120 255 265 163
Linear expansion coefficient TMA Flow direction (MD), -30 to 30℃ x10-6 mm/mm/℃ 77 33 22 55
Right angle direction (TD), -30~30℃ 83 71 49 76
Molding shrinkage rate Idemitsu method Flow direction (MD) mold temperature 80℃ 0.4 - 1.4 0.2 - 0.5 0.1 - 0.4 0.4 - 1.3
Right angle direction (TD) mold temperature 80℃ 0.4 - 1.2 0.3 - 0.7 0.3 - 0.7 0.5 - 1.5
Flow direction (MD) mold temperature 150℃
Right angle direction (TD) mold temperature 150℃
Flammability/UL related standards, etc.
Combustion quality UL94 HB minimum thickness mm 1.5 1.5 HB equivalent
V-0 minimum thickness
5VA minimum thickness
Temperature index RTI Elec
Imp
Str
UL 746B 50 50
50 50
50 50
Tracking resistance (CTI) IEC 60112, Solution A PLC level 0
equivalent
0
equivalent
0
equivalent
High voltage arc tracking rate (HVTR) UL 746A PLC level
Hot wire ignitability (HWI) UL 746A @3.0mm PLC level
@1.5mm
@0.75mm
High current arc ignitability (HAI) UL 746A @3.0mm PLC level
@1.5mm
@0.75mm
arc resistance ASTM D495 PLC level 6 equivalent 6 equivalent 6 equivalent
Electrical characteristics
Volume resistivity IEC 60093 Ohm-cm >1E+16 >1E+16 >1E+16
Withstand voltage (dielectric breakdown strength) ASTM D149 kV/mm 70 50 50
relative dielectric constant IEC 60250 1MHz 2.9 3.1 3.4
Dissipation tangent IEC 60250 1MHz <0.001 <0.001 <0.001
Standard molding conditions
cylinder temperature 280 - 310 280 - 310 280 - 310 280 - 310
mold temperature ※1 130-155 130-155 ※1
Drying conditions 120℃, 3-5 hours 120℃, 3-5 hours 120℃, 3-5 hours 80℃, 3-5 hours

*1 Please contact our sales representative.

  • The data presented in this document are representative of measurements obtained under specific conditions.

  • The uses described in this document do not guarantee the results of applying this product to those uses.

  • When using the product for the purposes introduced in this document, please be careful about infringing on industrial property rights (patent rights, utility model rights, design rights, trademark rights). (Our company is not responsible for infringement of industrial property rights.)

  • It cannot be used for medical equipment or medical products.

  • If the product is to be used for food utensils or packaging, please have our sales representative thoroughly confirm the compatibility of the applicable grade with relevant laws and regulations (Food Sanitation Law, etc.) in advance and sign the delivery specifications. I will do it.

  • It is the customer's responsibility to check the compliance of products processed by the customer with various laws and regulations using our products as raw materials.

  • Please note that the contents of this document are subject to change without notice due to improvements.

  • The flammability described in this document is an evaluation based on small-scale tests, and cannot be directly applied to the evaluation of danger in an actual fire.