Glass fiber reinforced, UL94 V-0 grade
Grade classification | glass fiber content | grade name | Purpose |
---|---|---|---|
Glass fiber reinforced, UL94 V-0 grade | GF30% | C832 | electronic parts, electrical machinery |
GF30% | S834 | ||
GF30% | S931 | Home appliances, electronic parts | |
GF30% | S932 | ||
GF22% | EA522 | electronic parts, electrical machinery | |
GF30% | EA533 |
-
The uses described in this document do not guarantee the results of applying this product to those uses.
-
When using the product for the purposes introduced in this document, please be careful about infringing on industrial property rights (patent rights, utility model rights, design rights, trademark rights). (Our company is not responsible for infringement of industrial property rights.)
-
It cannot be used for medical equipment or medical products.
-
If the product is to be used in food utensils or packaging, please have our sales representative thoroughly confirm the compatibility of the applicable grade with relevant laws and regulations (Food Sanitation Law, etc.) before signing the delivery specifications. I will do it.
-
It is the customer's responsibility to check the compliance of products processed by the customer with various laws and regulations using our products as raw materials.
-
Please note that the contents of this document are subject to change without notice due to improvements.
C832
standard grade
S931, EA522, EA533
Registered to UL746B.
Reinforced with 30% glass fiber and registered with UL94V-0.
Suitable for electrical, electronic, and other applications that require long-term heat resistance.
Zarec's UL746B certified temperature (℃)
grade | Electrical | mechanical | ||
---|---|---|---|---|
V-0 thickness [mm] | Impact | No impact | ||
S931 | 0.75 | 130 | 120 | 130 |
EA522 | 1.50 | 125 | 120 | 120 |
EA533 | 1.50 | 125 | 120 | 120 |
S834
CTI=0
S932
high flow
Physical properties table
July 11, 2023
Test items | Measurement method | (Measurement condition) | Unit | C832 | S834 | S931 | S932 |
---|---|---|---|---|---|---|---|
ISO material display | >PS-ST-GF30FR(17)< | >PS-ST-GF30FR(17)< | >PS-ST-GF30FR(17)< | >PS-ST-GF30FR(17)< | |||
physical properties | |||||||
density | ISO 1183 | g/cm3 | 1.41 | 1.42 | 1.45 | 1.45 | |
glass fiber content | wt% | 30 | 30 | 30 | 30 | ||
Water absorption rate | ISO 62 | 24h 50%RH | % | 0.02 | 0.02 | 0.02 | 0.02 |
Mechanical properties | |||||||
Tensile breaking strength | ISO 527 | MPa | 115 | 115 | 110 | 110 | |
tensile modulus | MPa | 10,600 | 10,600 | 10,500 | 10,500 | ||
Tensile elongation at break | % | 1.6 | 1.6 | 1.5 | 1.5 | ||
bending strength | ISO 178 | MPa | 170 | 170 | 170 | 170 | |
bending modulus | MPa | 10,000 | 10,000 | 10,300 | 10,300 | ||
Izod impact strength | ISO 180 | With notch at 23℃ | kJ/ m2 | 9 | 9 | 8 | 9 |
No notch at 23℃ | 29 | 29 | 26 | 24 | |||
Charpy impact strength | ISO 179 | With notch at 23℃ | kJ/ m2 | 10 | 10 | 9 | 10 |
No notch at 23℃ | 28 | 28 | 28 | 31 | |||
thermal properties | |||||||
Load deflection temperature | ISO 75A | 1.8MPa | ℃ | 245 | 245 | 230 | 230 |
ISO 75B | 0.45MPa | 265 | 265 | 265 | 265 | ||
Linear expansion coefficient | TMA | Flow direction (MD), -30 to 30℃ | x10-6 mm/mm/℃ | 20 | 20 | 19 | 18 |
Right angle direction (TD), -30~30℃ | 40 | 40 | 42 | 38 | |||
Molding shrinkage rate | Idemitsu method | Flow direction (MD) | % | 0.1 - 0.4 | 0.1 - 0.4 | 0.1 - 0.4 | 0.1 - 0.4 |
Right angle direction (TD) | 0.5 - 0.8 | 0.5 - 0.8 | 0.3 - 0.7 | 0.3 - 0.7 | |||
Flammability/UL related standards, etc. | |||||||
Combustion quality | UL94 | HB minimum thickness | mm | - | - | - | - |
V-0 minimum thickness | 1.5 | 1.6 | 0.75 | 0.8 | |||
5VA minimum thickness | - | - | - | - | |||
Temperature index RTI Elec Imp Str |
UL 746B | ℃ | 50 | 50 | 130 | 50 | |
50 | 50 | 120 | 50 | ||||
50 | 50 | 130 | 50 | ||||
Tracking resistance (CTI) | IEC 60112, Solution A | PLC level | 1 equivalent | 0 | 1 | - | |
High voltage arc tracking rate (HVTR) | UL 746A | PLC level | - | - | 3 | - | |
Hot wire ignitability (HWI) | UL 746A | @3.0mm | PLC level | - | - | - | - |
@1.5mm | - | - | 2 | - | |||
@0.75mm | - | - | 3 | - | |||
High current arc ignitability (HAI) | UL 746A | @3.0mm | PLC level | - | - | - | - |
@1.5mm | - | - | 0 | - | |||
@0.75mm | - | - | 0 | - | |||
arc resistance | ASTM D495 | PLC level | 6 equivalent | 6 equivalent | 6 | - | |
Electrical characteristics | |||||||
Volume resistivity | IEC 60093 | Ohm-cm | >1E+16 | >1E+16 | >1E+16 | >1E+16 | |
Withstand voltage (dielectric breakdown strength) | ASTM D149 | kV/mm | 35 | 35 | 35 | 35 | |
relative dielectric constant | IEC 60250 | 1MHz | 3 | 3 | 3 | 3.1 | |
Dissipation tangent | IEC 60250 | 1MHz | 0.002 | 0.002 | 0.002 | 0.003 | |
Standard molding conditions | |||||||
cylinder temperature | ℃ | 280 - 310 | 280 - 310 | 280 - 310 | 280 - 310 | ||
mold temperature | ℃ | 130-155 | 130-155 | 130-155 | 130-155 | ||
Drying conditions | 120℃, 3-5 hours | 120℃, 3-5 hours | 120℃, 3-5 hours | 120℃, 3-5 hours |
Test items | Measurement method | (Measurement condition) | Unit | EA522 | EA533 |
---|---|---|---|---|---|
ISO material display | >PS-ST-GF20FR(17)< | >PS-ST-GF30FR(17)< | |||
physical properties | |||||
density | ISO 1183 | g/cm3 | 1.32 | 1.38 | |
glass fiber content | wt% | 22 | 30 | ||
Water absorption rate | ISO 62 | 24h 50%RH | % | 0.01 | 0.01 |
Mechanical properties | |||||
Tensile breaking strength | ISO 527 | MPa | 100 | 125 | |
tensile modulus | MPa | 8,000 | 10,700 | ||
Tensile elongation at break | % | 2.3 | 2 | ||
bending strength | ISO 178 | MPa | 155 | 195 | |
bending modulus | MPa | 7,500 | 10,500 | ||
Izod impact strength | ISO 180 | With notch at 23℃ | kJ/ m2 | 11 | 10 |
No notch at 23℃ | 34 | 33 | |||
Charpy impact strength | ISO 179 | With notch at 23℃ | kJ/ m2 | 12 | 12 |
No notch at 23℃ | 39 | 42 | |||
thermal properties | |||||
Load deflection temperature | ISO 75A | 1.8MPa | ℃ | 230 | 245 |
ISO 75B | 0.45MPa | 265 | 265 | ||
Linear expansion coefficient | TMA | Flow direction (MD), -30 to 30℃ | x10-6 mm/mm/℃ | 24 | 19 |
Right angle direction (TD), -30~30℃ | 53 | 39 | |||
Molding shrinkage rate | Idemitsu method | Flow direction (MD) | % | 0.2 - 0.4 | 0.1 - 0.3 |
Right angle direction (TD) | 0.5 - 0.7 | 0.4 - 0.7 | |||
Flammability/UL related standards, etc. | |||||
Combustion quality | UL94 | HB minimum thickness | mm | - | - |
V-0 minimum thickness | 1.5 | 1.5 | |||
5VA minimum thickness | - | - | |||
temperature index RTI Elec Imp Str |
UL 746B | ℃ | 125 | 125 | |
120 | 120 | ||||
120 | 120 | ||||
Tracking resistance (CTI) | IEC 60112, Solution A | PLC level | 1 | 2 | |
High voltage arc tracking rate (HVTR) | UL 746A | PLC level | 0 | 0 | |
Hot wire ignitability (HWI) | UL 746A | @3.0mm | PLC level | 0 | 0 |
@1.5mm | 1 | 1 | |||
@0.75mm | - | - | |||
High current arc ignitability (HAI) | UL 746A | @3.0mm | PLC level | 0 | 0 |
@1.5mm | 0 | 0 | |||
@0.75mm | - | - | |||
arc resistance | ASTM D495 | PLC level | 5 | 6 | |
Electrical characteristics | |||||
Volume resistivity | IEC 60093 | Ohm-cm | >1E+16 | >1E+16 | |
Withstand voltage (dielectric breakdown strength) | ASTM D149 | kV/mm | 35 | 31 | |
relative dielectric constant | IEC 60250 | 1MHz | 3 | 3.2 | |
Dissipation tangent | IEC 60250 | 1MHz | 0.001 | 0.002 | |
Standard molding conditions | |||||
cylinder temperature | ℃ | 280 - 310 | 280 - 310 | ||
mold temperature | ℃ | 130-155 | 130-155 | ||
Drying conditions | 120℃, 3-5 hours | 120℃, 3-5 hours |
-
The data presented in this document are representative of measurements obtained under specific conditions.
-
The uses described in this document do not guarantee the results of applying this product to those uses.
-
When using the product for the purposes introduced in this document, please be careful about infringing on industrial property rights (patent rights, utility model rights, design rights, trademark rights). (Our company is not responsible for infringement of industrial property rights.)
-
It cannot be used for medical equipment or medical products.
-
If the product is to be used for food utensils or packaging, please have our sales representative thoroughly confirm the compatibility of the applicable grade with relevant laws and regulations (Food Sanitation Law, etc.) in advance and sign the delivery specifications. I will do it.
-
It is the customer's responsibility to check the compliance of products processed by the customer with various laws and regulations using our products as raw materials.
-
Please note that the contents of this document are subject to change without notice due to improvements.
-
The flammability described in this document is an evaluation based on small-scale tests, and cannot be directly applied to the evaluation of danger in an actual fire.